COMSPHERE 392xPlus Modems
14-28 October 1998 3920-A2-GH30-40
Table 14-3
(12 of 15)
392xPlus S-Registers
S-Register
DCP LCD
Command
Sequence
Description
S74 Network Position Identification. Register identifies each modem as either a
control or tributary modem.
Register has the following values:
0 = Tributary
1 = Control
The factory setting is Tributary.
Configure\Edit\
Misc
S75 Network Management Address. Register determines the modem’s network
address. This address is used when accessing the modem from the
6700 Series NMS.
Enter a value from 0 (network address 001) to 255 (network address 256).
The factory setting is 0.
Configure\Edit\
Dial
S76 Autorate (Dial Line). Register determines if Autorate is used on dial lines when
connected in V.32bis, V.32terbo, or V.34 mode.
Register has the following values:
0 = Enable
1 = Disable
2 = Start@48
3 = Start@96
4 = Fast
The factory setting is Enable.
Configure\Edit\
Dial Line
S78 V.32bis Automode (Dial Line). Register allows the modem (when operating on
dial lines) to automatically detect and connect to the remote modem’s
modulation scheme.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
Configure\Edit\
Dial Line
S81 2-Wire Leased Line Signal Quality Retrain. Forces the modem to retrain if the
SQ (Signal Quality) LED is on for more than the specified number of seconds.
Register has the following values:
0 = Disable
1–5 = Number of seconds SQ LED must be on to force a retrain
The factory setting is Disable.
Configure\Edit\
Leased Line
S82 Autorate (Leased Line). Register determines if Autorate is used on leased
lines when connected in V.32bis, V.32terbo, or V.34 mode.
Register has the following values:
0 = Enable
1 = Disable
4 = Fast
5 = GainHit
The factory setting is Enable.
Configure\Edit\
Leased Line