Zhone 3920Plus Bedienerhandbuch Seite 150

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 354
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 149
COMSPHERE 392xPlus Modems
5-74 October 1998 3920-A2-GH30-40
Table 5-14
(2 of 5)
Miscellaneous Configuration Options Singleport Mode A
Access frm Remt: Enable
Nxt Enable Disable
Access from Remote. Determines if your modems DCP can be accessed by a remote modem via the VF line.
CAUTION: If this configuration option is disabled, the modem cannot be accessed by another modem.
Enable Allows access from a remote modem.
Disable Does not allow access from a remote modem.
NOTE: The remote modem must be a Model 3920Plus or Model 3921Plus modem.
The AT command is S-Register S55 = n, where n is 0 for Enable and 1 for Disable.
RemAccssPasswrd: 00000000
Nxt " 00000000
Remote Access Password. Allows the entry of a password for establishing control of a remote modem from the DCP of
a local modem. The same password must be used in both the local and remote modem.
CAUTION: A remote access password should be selected for security purposes.
NOTE: If the Access from Remote configuration option is set to Disable, the password has no effect.
The AT command equivalent is S-Registers S56 = n, S57 = x, S58 = y, and S59 = z, where n is the leftmost pair of
digits, x is the second pair of digits, y is the third pair of digits, and z is the rightmost pair (or fourth) pair of digits. For
example, if the remote access password is 12345678, then the value for S56 is 1 and 2, and the value for S59 is 7
and 8.
Dir#1_Callback: Disable
Nxt Disable Enable
Directory Location 1 Callback. This configuration option controls whether or not the modems single number callback
function is used.
Disable Modem does not use the single number callback function.
Enable Modem answers a call, disconnects, and dials the number stored in directory location 1.
NOTE: This function is disabled if dial access security is enabled.
The AT Command to Disable is S-Register S67 = 0.
The AT Command to Enable is S-Register S67 = 1.
Callback Delay: Disable
Nxt Disable 20sec 40sec 1min 2min 3min
This configuration option only appears if Dir#1 Callback is enabled.
Callback Delay. Determines the amount of time between disconnect confirmation and callback origination.
Disable No time is specified. The default delay is 10 seconds.
20sec 3min The delay is set to the specified duration.
The AT command is S-Register S60 = n, where n is 0 for Disable, 1 for 20sec, 2 for 40sec, 3 for 1min, 4 for 2min, and
5 for 3min.