COMSPHERE 392xPlus Modems
5-38 October 1998 3920-A2-GH30-40
Table 5-7
(2 of 8)
DTE Interface Configuration Options Singleport Mode A
Async DTE Rate: 19200
Nxt 19200 115200 76800 57600 38400 28800 14400 12000 9600 7200 4800 2400 1200 0300
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous DTE Data Rate. Identifies the asynchronous DTEs operating rate to the modem. Data rates from
115,200 bps to 300 bps are supported.
NOTE: To prevent losing data in 115,200 bps applications using rates higher than 19,200 bps, a 16650 UART on the
PCs serial port may be required, as well as a communications package which can take advantage of its 16-byte
buffer. In addition, a 386 PC (25 MHz or faster) is required, and the RS232 cable length must be minimized to
reduce capacitance.
NOTE: To configure the Async DTE Rate differently than the modem rate, ensure that the Err Contrl Mode configuration
option (see the V.42/MNP/Buffer — Singleport Mode section) is not set to DirectMode.
The AT prefix determines Async DTE Rate.
Asyn #Data Bits: 8
Nxt 8 7 9(DirectMde) 6(DirectMde)
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Number of Data Bits. Determines if the asynchronous data length is composed of 6, 7, 8, or 9 data bits.
This data length excludes start, parity, and stop bits.
8 Sets data length to 8 data bits.
7 Sets data length to 7 data bits.
9(DirectMde) Sets data length to 9 data bits. Only valid when Err Contrl Mode configuration option is set to
DirectMode.
6(DirectMde) Sets data length to 6 data bits. Only valid when Err Contrl Mode configuration option is set to
DirectMode.
NOTE: If the DTE Dialer Type configuration option is set to AT or V.25bis Async, then the total character size must
equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data
bits with even parity and 1 stop bit. The total character size for Error Control mode, DirectMode, or BufferMode
must be 11 bits or less.
The AT prefix determines the async character length.
Asyn Parity Bit: None
Nxt None Even Odd Mark Space
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Parity Bit. Determines the type of asynchronous parity bit. The parity of the DTE must match the parity of
the modem. Parity options include None, Even, Odd, Mark, or Space.
None No parity bit is used.
Even Parity bit is set so that total number of 1s in data bits plus parity bit is even.
Odd Parity bit is set so that total number of 1s in data bits plus parity bit is odd.
Mark Parity bit is always set to 1. Only valid if Asyn #Data Bits configuration option is set to 7.
Space Parity bit is always set to 0. Only valid if Asyn #Data Bits configuration option is set to 7.
NOTE: If the DTE Dialer Type configuration option is set to AT or V.25bis Async, then the total character size must
equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data
bits with even parity and 1 stop bit. The total character size for Error Control mode, DirectMode, or BufferMode
must be 11 bits or less.
The AT prefix determines parity of the async character.