Seitenansicht 100
General Features 4-27
IMACS-200 General Features SYS port Error Messages
4.6 SYS port Error Messages
Refer to Appendix B in this Guide for further information on Error Messages regarding this
port.
4.7 SYS port Troubleshooting
On power-up, the SYS port performs a self-test. This is the only diagnostic available for the
SYS. A “healthy” active SYS will have a green LED lit on the front panel.
The indications that a SYS is not on-line are:
Continuous amber alarm LED on front panel or the LEDs continually cycling through the
orange, green, red, blank sequence.
Inability to communicate with the system by any means (VT-100 Term, Telnet, etc.).
If the SYS port is determined to be faulty, replace it and return the faulty unit for repair to the
location specified by your distributor.