3. Commands
4821-A2-GB21-00 July 2004 3-73
Configure SNTP Interval
Configure Syslog
This command configures the Syslog threshold and rate limiting.
Configure Syslog Rate Limiting
configure sntp interval {interval}
Minimum Access Level: Administrator
The configure sntp interval command specifies the frequency that the unit should make SNTP
requests to update the date and time. The units makes a time request whenever it powers on,
then it makes periodic requests based in the interval specified.
interval – The period, in hours, between SNTP requests. Valid values are 1–24. The default is 24
hours.
Example:
PDYN# configure sntp interval 12
configure syslog rate-limiting {disabled | enabled}
Minimum Access Level: Administrator
The configure syslog rate-limiting command determines whether duplicate messages are
written to the system log.
disabled – All messages (satisfying the syslog threshold setting) are written to the system log.
This is the default.
enabled – Consecutive duplicate messages are written to the system log only if they are received
more than five minutes apart.
Example:
PDYN# configure syslog rate-limiting disabled