Zhone 4821-A2 Technical Information Seite 56

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 184
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 55
3. Commands
3-32 July 2004 4821-A2-GB21-00
Configure Interface DSL Profile Alarm Upstream Error Seconds
Configure Interface DSL Profile Alarm Upstream Loss of Frame Seconds
configure interface dsl-profile-alarm upstream-es {es} {profile_name }
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm upstream-es command modifies the upstream errored
seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
es - SNMP trap is sent if the number of errored seconds
events in a 15-minute interval meets or exceeds the selected value (0–900
seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm upstream-es 500 adsl_alarm_profile1
configure interface dsl-profile-alarm upstream-lofs {lofs} {profile_name }
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm upstream-lofs command modifies the upstream
los-of-frame-seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
lofs - if the number of LOFS events in a 15-minute interval meets or exceeds the
selected value (0–900 seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl profile-alarm upstream-lofs 500 adsl_alarm_prof1
Seitenansicht 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 183 184

Kommentare zu diesen Handbüchern

Keine Kommentare