3. Commands
4821-A2-GB21-00 July 2004 3-53
Configure Interface Ethernet Mode
configure interface ethernet {port_id} mode {auto | manual}
Minimum Access Level: Administrator
The configure interface ethernet mode command specifies whether the duplex mode and rate are
automatically set, and the crossover type automatically sensed.
port_id – Identifies the Ethernet port to be configured. The possible forms of the identifier are described
in Ethernet Port ID in Chapter 1, System Concepts.
mode – Valid choices are:
auto – The unit automatically senses the rate and duplex mode. This is the default.
manual – The administrator must set the rate and duplex mode.
Example:
PDYN# configure interface ethernet eth1 mode manual